VHP Sterilization Chamber

¥0.00 Sold out
Material:
SUS304/316L Stainless Steel
Vaporization Power:
Clean Compressed Air
Sterilization Efficacy:
6-log
Sterilization Time:
<120 min
Cleanliness Class:
Class B
Power Supply:
380V, 50Hz,3kW

VHP (Vaporized Hydrogen Peroxide) Decontamination Chamber is normally used for sterilization of outer surface of any object, which is not suitable for AUTOCLAVE & compatible with HYDROGEN PEROXIDE in vapour phase.

Get a Free Quote

Technical Specifications & Parameters:

Model Outer Size Inner Size Nominal Volume Cleanliness Class Sterilization Efficacy Power
/ W×D×H (mm) W'×D'×H' (mm) (L) / / (kW)
LATM288 1200×800×2000 600×800×600 288 Class B 6-log 3
LATM512 1400×800×2200 800×800×800 512 Class B 6-log 3
LATM1000 1600×1060×2100 1000×1000×1000 1000 Class B 6-log 3
LATM1440 1600×1260×2300 1000×1200×1200 1440 Class B 6-log 3

Material Application Structure Sterilization Time Vaporization Power Sterilization Efficacy
SUS304/316L Stainless Steel Pharmaceuticals, Food & Beverage, Electronics Fully Enclosed <120 min. Clean Compressed Air 6-log

Sterilization Media Maintenance Mode Inlet Air Purification Cycling Mode Validation Document System Monitoring Soft System
30% Medical Grade H2O2 Side Access/Up-Down Access H14 Direct Exhaust 4Q/FAT/SAT Increase concentration Display the current step, remaining time and working status of main parts,time setting, system parameter setting, alarm information, online data monitoring,manual and automatic switching, sterilization batch input, validation information,PDF report, formula management

Sterilization Process & Vaporizer Schematic Diagram:

Airflow Diagram
Structure Diagram

Operation Principle:

A01

A built-in VHP generator heats up the hydrogen peroxide, converting it from liquid to vapour, then blown into the chamber, creating a lethal environment capable of killing bacteria, viruses and fungi. Each step of the process is fully controlled, guaranteeing perfect performance.

Product Description:

A01

VHP Decontamination Chamber is designed for two different zone of area, for transferring of product from lower classified zone to higher classified zone (Non– sterile area to Sterile area), without effecting the balancing of respective zone, containment free product transfer to higher classified zone. The Unit is especially suitable for GMP regulated pharmaceutical companies manufacturing drugs aseptically.

Characteristics & Features:

Rapid Sterilization Cycles

A01

Sterilization process <120min. to realize multiple sterilization operations one day.

Automated Smart Control

A02

Fully automatic operate, menu can be saved and invoked.

Instant Emergency Stop

A03

Emergency Stop.

Low Reagent Consumption

A04

Very low hydrogen peroxide consumption.

Eco-Friendly VHP Filter

A05

Decomposition filter can effectively reduce the concentration of VHP remain Reduce the impact on environment and personnel.

Space-Saving Maintenance

A06

Through up down side to reduce the inspection space.

Optimized Corner Design

A07

Corner sterilization pass box which will increase factory space utilization ratio, and improve the distribution.

Stable Pressure Air

A01

Adopts clean compressing air for vaporization power which can reduce the impact of the pressure differential when taking air from the room.

Real-World Success Stories in Pharmaceutical Manufacturing

VHP Sterilization Chamber Case Diagram

001/002

VHP Sterilization Chamber Case Diagram

002/002